Test Method
Hold the TensION at a distance from the ionising points / emitters. If a high voltage is present, a red indicator in the plastic tip will illuminate. To get an indication of proper functioning of the Simco-Ion equipment all the emitters should be checked.
Minimum distance from the TensION to the ionising emitters or charging points must be obtained. Refer to the table below:
Test Method
Hold the TensION at a distance from the ionising points / emitters. If a high voltage is present, a red indicator in the plastic tip will illuminate. To get an indication of proper functioning of the Simco-Ion equipment all the emitters should be checked.
Minimum distance from the TensION to the ionising emitters or charging points must be obtained. Refer to the table below:
Operating Voltage | Minimum distance |
3,3 kV | 5 mm |
4 kV | 6mm |
5 kV | 10 mm |
7 kV | 13 mm |
10 kV | 20 mm |
30 kV | 80 mm |
Technical specifications
Power | 2 size AAA batteries (included) |
Measuring distance | contactless (see table above) |
Weight | 40 grams |
Material | Radilon-S HS(a), BE 170MO IP64 |
Dimensions | Length 148 mm, diameter maximum 17 mm |
Ambient temperature | -10°C – +55°C |